High Flex Power and Control Cable

for continuous linear movements in energy chains

300V / 600V / 1000V UL AWM

High Flex Power and Control Cables are the fabric of automated industrial machines and robotic systems. These cables are typically used in conjunction with energy chains or cable carriers that support and guide the cables through motion. Standard flexible cables would not be able to withstand the continuous bending and motion due to their construction. High flex cables are designed with this movement in mind, from the stranding type, pitch length, shielding, insulation and jacket material and Right Hand Industrial can help you with the proper selection and sourcing. 

Control, multi-conductor

Unshielded, multi-conductor control

PVC jacket, gray, unshielded control cable, continuous flex, 600V UL 80°C

  • Jacket: PVC, gray

  • Insulation: TPE High Glide, black w/ white #’s, GN/YL ground

  • Voltage: 600V UL AWM 80C°

  • Range: Metric: 0.5mm² – 4mm² (AWG 21 – 14) up to 50 conductors

PVC jacket, gray, unshielded control cable, continuous flex, 600V UL 90°C

  • Jacket: PVC, gray

  • Insulation: TPE High Glide, black w/ white #’s, GN/YL ground

  • Voltage: 600V UL AWM 105C°

  • Range: Metric: 0.5mm² – 4mm² (AWG 21 – 14) up to 50 conductors

PUR jacket, gray, unshielded control cable, continuous flex, 300V/600V UL

  • Jacket: PUR, gray

  • Insulation: TPE High Glide Insulation, black w/ white #’s, GN/YL ground

  • Voltage: 300V UL AWM 20233 (AWG 21-18), 600V UL AWM 20234 (AWG 18-14)

  • Range: Metric: 0.5mm² – 2.5mm², (AWG 21 -14) up to 25 conductors

PUR jacket, gray, unshielded control cable, continuous flex, 600V UL, 1000V CSA

  • Jacket: PUR, gray

  • Insulation: special TPE, black w/ white #’s, GN/YL ground

  • Voltage: 600V UL AWM 21223 80C°, 1000V CSA

  • Range: Metric: 0.5mm² – 50mm² (AWG 20 -1) up to 61 conductors

Shielded, multi-conductor control

PVC jacket, gray, shielded control cable, continuous flex, 600V UL 80°C

  • Jacket: PVC, gray

  • Insulation: TPE High Glide, black w/ white #’s, GN/YL ground

  • Sub Jacket: PVC

  • Shielding: tinned copper braid shield

  • Voltage: 600V UL AWM 80C°

  • Range: Metric: 0.5mm² – 4mm² (AWG 21 – 14) up to 34 conductors

PVC jacket, gray, shielded control cable, continuous flex, 600V UL 90°C

  • Jacket: PVC jacket, gray

  • Insulation: TPE High Glide Insulation , black w/ white #’s

  • Sub-jacket: PVC

  • Shielding: tinned copper braid shield

  • Voltage: 600V UL AWM 105C°

  • Range: Metric conductor: 0.5mm² – 4mm² (AWG 21 – 14) up to 34 conductors

PUR jacket, gray, shielded control cable, continuous flex, 600V UL 

  • Jacket: PUR jacket, gray

  • Insulation: TPE High Glide Insulation, black w/ white #’s, GN/YL ground

  • Sub-jacket: PVC sub-jacket

  • Shielding: tinned copper braid shield

  • Voltage: 300V UL AWM 20233 (AWG 21-18), 600V (AWG 18-14) UL AWM 20234

  • Range: Metric: 0.5mm² – 2.5mm² (AWG 21 -14) up to 25 conductors

PUR jacket, gray, shielded control cable, continuous flex, 600V UL, 1000V CSA

  • Jacket: PUR, gray

  • Insulation: special TPE insulation, black w/ white #’s, GN/YL ground

  • Sub-jacket: TPE

  • Shielding: tinned copper braid

  • Voltage: 600V UL AWM 21223 80C°, 1000V CSA

  • Range: Metric: 0.5mm² – 35mm², AWG 20 – 2, up to 36 conductors

TPE jacket, yellow, shielded control cable, continuous flex, 600V UL, CSA

  • Jacket: TPE, yellow

  • Insulation: FEP, color coded

  • Sub-jacket: FEP

  • Shielding: tinned copper braid

  • Voltage: 600V UL, CSA, MSHA

  • Range: AWG 24 – 16, up to 65 conductors

Power, multi-conductor

Unshielded, multi-conductor power

PUR jacket, black, unshielded power cable, continuous flex, 1000V UL

  • Jacket: PUR jacket, black

  • Insulation: TPE insulation

  • Voltage: 1000V UL AWM 80C°

  • Range: 16mm² – 50mm² (AWG 21 – 14), up to 5 conductors

TPE jacket, yellow, unshielded power cable, continuous flex, 600V UL

  • Jacket: TPE, yellow

  • Insulation: TPE

  • Voltage: 1000V UL AWM 21223 80C°

  • Range: 4 – 2 AWG, 3 conductors

PUR jacket, orange, unshielded power cable, continuous flex, 1000V UL

  • Jacket: PUR jacket, orange

  • Insulation: special TPE insulation

  • Voltage: 1000V UL AWM 21223 80C°, CSA

  • Metric: 1.5mm² – 50mm² (AWG 16 – 1), 4 conductors

  • up to 5 conductors

Shielded, multi-conductor power

PUR jacket, orange, shielded motor power cable, 1000V UL

  • Jacket: PUR jacket, orange

  • Insulation: TPE insulation

  • Shielding: tinned copper braid shield

  • Voltage: 1000V UL AWM 21223 80C°

  • Range: 1.0mm² – 50mm² (AWG 18 – 1) 4 condcutors

Power, single conductor

Unshielded, single conductor power

PUR jacket, black, unshielded single conductor motor power, continuous flex, 1000V UL

  • Jacket: PUR, black (also offered in green/yellow)

  • Sub-jacket: TPE

  • Voltage: 1000V UL AWM 80C°

  • Range: 6mm² – 120mm² (AWG 10 – 4/0)

Shielded, single conductor power

PUR jacket, black, shielded single conductor motor power, continuous flex, 1000V UL

  • Jacket: PUR, black

  • Sub-jacket: TPE

  • Shielding: tinned copper braid shield

  • Voltage: 1000V UL AWM 80C°

  • Range: 6mm² – 70mm² (AWG 10 – 2/0)

Customer Service

Customer service is paramount here at Right Hand Industrial! Request a quote from us today, and you will hear back from us today. Place an order with us today, and you'll get an order confirmation from us today. Tracking information is forwarded as soon as it's available and monitored until delivery. We are here to help, quickly!